Phone Phone E-mail E-mail
Please add another product for comparison.

Product


The Nubert XRC Android Interface is a USB clip-on microphone for Android mobile devices that can be used to calibrate suitable Nubert speakers and other products for the room situation.

With the X-Room Calibration, the sound image of the speakers of the nuPro X RC generation, the subwoofers of the nuSub XW series and the integrated amplifier nuConnect ampX can be adjusted to the spatial conditions. The equalisation reliably reduces room modes such as booming or dips in the low-frequency reproduction range and thus ensures a more pleasing listening experience with powerful, dry and impulse-true bass.

This calibration is largely automatic with the help of the free Nubert X-Remote app on a smartphone or tablet. However, for technical reasons, the measurement process can only be carried out on Apple iOS devices. Android smartphones and tablets do not provide reliable measurement results due to the large number of microphones used with different parameters. The solution is the Nubert XRC Android Interface: a compact plug-in module that connects to the USB input (type C) of the mobile device and gives the X-Remote app access to a precise measurement microphone and a sophisticated analogue-to-digital converter. With this practical USB dongle, the measuring tone of the XRC system or the room response can be precisely recorded, after which the app can calculate the optimal correction curve and transmit it to the signal processor.

This makes Nubert X-Room Calibration one of the few audio correction systems offered not only for iOS devices but also for Android devices - if not the only one.

The Nubert XRC Android Interface can be used on all Android devices running the current version of the Nubert X-Remote app and which have a suitable USB-C input. If necessary, a USB adapter can be used.

Scope of delivery

  • 1 x Nubert XRC Android Interface
  • 1 x quick start guide

The interface is powered via the USB port of the mobile device.

Responsible person

Nubert electronic GmbH

Address

Nubertstraße 1, 73529 Schwäbisch Gmünd, Deutschland

Contact

Email: info@nubert.de Phone: +49 07171 - 8712-0

Safety Instructions

The entire operating manual, in particular the safety instructions, must be read in full before connecting and commissioning the device. For your own safety, be sure to follow all warnings and safety instructions in this manual and on the device. The user is not permitted to carry out any work on the device other than the described work. Keep this document so that you have access to it at all times. Furthermore, it must also be handed over to possible re-owners.

Intended Use

This device is exclusively intended for connection to mobile devices (here: smartphones or tablets with Android operating system) and exclusively for sound recording in connection with the appropriate Nubert app in dry rooms. Use the device only as described in this manual. Any other use (particularly safety-relevant or medical use, installation in open environments like IP-certified products) is considered improper and may result in property damage or even personal injury. Nubert electronic GmbH does not assume any liability for damages caused by improper use.

Handling

Caution!

Improper handling can damage the device itself and its USB plug as well as the USB socket of your mobile device!

  • Be careful not to bend the device!
  • Do not press on the side of the device while it is plugged in (in the mobile device)!
  • Keep strong mechanical shocks away from the device!

Caution! Heat Build-up

  • Do not operate the device near heat sources such as radiators or stoves!
  • Do not expose to direct sunlight!
  • Never place burning candles or similar open fire sources near the device!

Caution! Liquids and Objects

The device has no special protection against the intrusion of liquids or objects into the system.

  • No objects or foreign bodies may get into the device.
  • Never touch the device with wet hands!
  • Only use the device in a dry place!
  • The device must be protected from liquids of all kinds, including dripping and splashing water.
  • If the device is moved from a cold environment to a warm room, wait at least six hours until the device has reached room temperature and is dry before switching it on!
  • Do not use the device during rapid temperature changes!
  • If liquids or objects have entered the device, disconnect it immediately and contact Nubert electronic GmbH (info@nubert.de)!

Connection Instructions

General Connection Instructions

  • Only plug the USB plug of the device into USB sockets of designated mobile devices!
  • Make sure that the supply voltage is 5 V DC! The device must not be connected to other power supplies.
  • If the device is not used or is unsupervised for a longer period of time, disconnect the power supply by unplugging it from the mobile device!
  • Only use cables and accessories recommended by Nubert!

Care and Cleaning Tips

Caution!

  • Improper handling of the device may result in damage.
  • Always unplug the device from the mobile device before cleaning it!
  • Never use strong cleaning agents or solvents such as petrol, spirit, or similar!
  • Before recommissioning, make sure that all connections are correct, there are no short circuits, and all devices are completely dry.

Not the right one? We recommend taking a look at related products that you might like.

nuConnect ampX
Smart amp
€725.00 / Piece

nuSub XW-1200
Statement subwoofer
€995.00 / Piece

nuSub XW-800 slim
Slim design low end
€585.00 / Piece

nuSub XW-900
Low end for enveryone
€695.00 / Piece

Technical information


Subject to technical changes.